8.                         CONCLUSION AND RECOMMENDATION

8.1                       Conclusions

8.1.1                   No Action and Limit Level exceedance was recorded for air quality monitoring and construction noise monitoring in the reporting period.

8.1.2                   No Action and Limit Level exceedance was recorded for water quality in the reporting period.

8.1.3                   No Action / Limit exceedance was recorded for noise levels at stations (NMS1 and NMS2) in close proximity to the active ardeid night roosts in the monitoring period.

8.1.4                   No Action / Limit exceedance was noted for the ecological monitoring of birds during the reporting period.

8.1.5                   12 environmental site inspections and 12 landscape and visual site audits were carried out in the reporting period. Recommendations on mitigation measures were given to the Contractor for remediating the deficiencies identified during the site inspections.

8.1.6                   No environmental complaint, notification of summons and successful prosecution was recorded in the reporting period.

8.1.7                   The EM&A methodology has been effective in monitoring the environmental impacts of the Project and the effectiveness of the mitigation measures. The data collected were useful in determining whether the Project had caused unacceptable impacts on the sensitive receivers. Analysis of all EM&A data collected throughout the baseline and the impact monitoring periods demonstrated the environmental acceptability of the Project.

 


 

8.2                       Comment and Recommendations

8.2.1                   The recommended environmental mitigation measures, as proposed in the EIA report and EM&A Manual shall be effectively implemented to minimize the potential environmental impacts from the Project. The EM&A programme would effectively monitor the environmental impacts generated from the construction activities and ensure the proper implementation of mitigation measures.

8.2.2                   According to the environmental site inspections performed in the reporting period, the following recommendations were provided:

 

Air Quality Impact

·        The Contractor is reminded to increase watering for dust suppression during the demolition of sediment tank.

Construction Noise Impact

·        No specific observation was identified in the reporting period.

Water Quality Impact

·        Silty deposit in gullies should be cleaned at Zone 2.

·        Mitigation measure should be provided to prevent direct discharge of runoff near the main entrance.

·        The Contractor is reminded to de-silt the gullies near the main entrance.

·        The Contractor is reminded to prevent direct discharge of silt-laden water into the storm drain near the temporary transformer room.

Chemical Waste and Construction Waste Management

·        The Contractor is reminded to provide drip tray for the chemical containers.

Land Contamination

·        No specific observation was identified in the reporting period.

Ecological Impact

·        The Contractor is reminded to maintain and reinstate the bird curtain at the eastern site boundary.

Landscape and Visual Impact

·        Recommend to keep tree protection zone free of construction materials.

·        Recommend to provide regular maintenance check on dead branches and remove where necessary.

·        Please exercise caution when operating heavy machinery close to existing trees.

·        Provide damp hessian to cover exposed roots underneath existing footpath for Tree No. T168 – T173 near site entrance.

·        Remove stockpile under dripline area for Tree No. T173 – T188 near site entrance.

·        Avoid mechanical injury of crown and branches by sheet pile clamp during driving for Tree No. T168 – T173 near site entrance.

·        Contractor is reminded to keep planting area free of construction debris such as T020 & T022.

·        Caution when work next to existing trees at CLP station area.

·        Please exercise caution when working near existing trees at (former changing room area) CLP area.

·        Trunk damage observed for Tree T252, tree maintenance work is recommended.

Hazard to Life

·        No specific observation was identified in the reporting period.

Permit/ Licenses

·        No specific observation was identified in the reporting period.[This is the bookmark for the end of the main section. Do not put content past this point]


 [This is the bookmark for the end of the main section. Do not put content past this point]