Table 12 Water Quality Monitoring and Sampling Equipment
Parameter |
Equipment |
Model |
Range |
Equipment Accuracy |
Serial No. |
Temperature Dissolved
Oxygen Salinity pH Turbidity |
YSI
Water Quality Multipara meter Sonde |
Xylem
ProDSS |
Tem:
-5 to 50°C DO:
0-50mg/L DO%:
0-500% Sal:
0 to 70ppt pH:
0 to 14 pH units Turb:
0- 4000NTU |
Temp:
±0.2°C; DO:
±0.1mg/L or 1% for 0-20mg/L; ±8% for 20-50mg/L Sal:
±1% of reading or 0.1 ppt (whichever is greater) pH:
±0.2 units Turb:
±3% or 0.3NTU (FNU) (whichever greater) |
22D100436,
22C106561 |
Current Velocity and Direction |
Current
Meter |
Valeport Model 106 |
Speed: 0.03 to 5 m/s Direction: 0 to 360 |
Speed: ± 1.5% of reading
above 0.15m/s, ± 0.004 m/s below 0.15m/s Direction: ± 2.5o |
N/A |
Water Sampling |
Water
Sampler |
Aquatic
Research Instruments 2.2L Horizontal Water Sampler HWS2.2CP |
N/A |
N/A |
N/A |
Positioning |
DGPS |
GARMIN GPSMAP 78s |
N/A |
GPS:
±1m |
N/A |
Water Depth |
Echo
Sounder |
Garmin
ECHO 101 |
Maximum depth: 457.2 m |
0.1 m |
N/A |